Probes | Transmitters | Accessoires
|
Probes and transmitters used for measuring level and pressure of liquid and gas media. They are featured by a simple application, ruggedness, long lifetime, high precision and good time stability. According to the assembly they are divided into immersion probes and "dry-assembly" transmitters.
or send us an email with your request, we will be pleased to advise you.
|
 |
Level probes PPI 100 and PPI 120

|
Performance immersion probes for measuring levels of aggressive and corrosive media.
Advantages:
robust construction, simple installation, high operation reliability and a small measurement error.
Application:
level measurements in waterworks systems (drill-holes, wells, reservoirs), swimming pools, hydro power plant dams, water systems, regulation locks, irrigation systems ...
Technical data:
Power (two wire): 9-27VDC
Output: current 4-20mA
Measuring range (on customer demand): up to 300m
|
 |
Level and temperature probe PPI 200

|
Immersable probe that measures the level and temperature of aggressive and corrosive media.
Advantages:
probe diameter 22mm, compact construction, simple installation, high reliability.
Application:
level and temperature measurements in waterworks systems (drill-holes, wells, reservoirs), swimming pools, hydro power plant dams, water systems, regulation locks, industry, wells ...
Technical data:
Power (two wire): 9-27VDC
Output: 2 x current 4-20mA
Measuring range: level (on customer demand) up to 300m,
temperature 0 - 70 ° C
|
 |
Level or pressure transmitter PPI 110 and PPI 130

|
Compact and robust transmitters used to measure level or pressure of aggressive and corrosive liquids and gases, in applications where value review is not necessary.
The housing is made of stainless steel. The PPI 110 transmitter has a small measurement error (<0.2%) - used for precision measurements, the PPI 130 transmitter has a higher measurement error (up to 0.5%).
Mechanical connection:
G 1/2 or G 3/8 or hygiene connection.
Application: waterworks, heat supply, industry
Technical data:
Power: 9 - 27VDC (two wire – through the current loop)
Measuring range (on customer demand):
up to max. 300m or 30 bar
Output: current 4-20mA
Protection level: IP65 or IP68 (optional)
El. connection: cable or connector
|
 |
SMART level (pressure) transmitters SMN 201, SMN 211; (SMP 201, SMP 211)

|
Microprocessor level and pressure transmitters are characterized by great precision measurements, programmable measuring range, low consumption of el. current (current loop powered – two wire connection) and simple handling.
The transmitters with LED display (SMP 201 and SMN 201) allow excellent visibility in dark spaces and shafts. The transmitters with LCD display (SMP 211, SMN 211) offer two more output limit pairs.
Application:
level and pressure measurement in waterworks (tanks, pipes), heat supplies, swimming pools, industry ...
Technical data:
Power (two wire): 8-27VDC - 24VDC typical
Output: current 4-20mA, two limit pairs (SMP 211, SMN 211)
Programmable measuring range
Display on the LED or LCD screen:
level or pressure, flow, offset movement, damping
factor and setting of the measuring range
|
 |
Level or pressure transmitter DMN 201, DMT 201

|
A transmitter used for measuring level or pressure of aggressive and corrosive liquids and gases. Housing is stainless steel, the head polycarbonate.
Application:
waterworks, heat supply, industry ...
Technical data:
Power: 9-27VDC, typical 24VDC
Measuring range: on customer demand, up to 30 bar
Output: current 4-20mA, three limit pairs
|
 |
Differential pressure transmitter DMT 220

|
Thee transmitter converts the difference of two pressures of aggressive and corrosive liquids or gases into a current loop. The pressure connectors are made of stainless steel, the electronics with an LCD screen are held inside an ABS housing.
Application:
pump operation, filter saturation, differential switch ...
Technical data:
Power: 9 - 27VDC, typical 24VDC (two wire)
Measuring range (on customer demand): up to 30 bar
Output: current 4-20mA, limit pair |
 |
Level switch SPV 311

|
The level switch SPV 311 is made up of electronics mounted
in the el. cabinet and a probe which senses the level of liquids.
Application:
waterworks (protection of pumps against dry running, signaling the presence of water in the facility)
Technical data:
Power: 24VDC
Output: unpotential relay contacts |
| | TOP | |
|
WCS | Temperature Measurement
Resistance thermometers
Resistance thermometers perceive the temperature of gases and liquids. Depending on the method of installation and housing we offer different temperature sensors: spatial, atmospheric, immersion, channel... Temperature transmitters additionally contain electronics which have an output current loop and some also temperature review on a LED or LCD display. |
|
Resistance thermometer EKT 10

|
Semiconducting temperature sensor in a metal housing including connection cable
|
 |
Resistance thermometer EKT 11

|
Temperature sensor PT 100 or PT 1000 in a metal housing including connection cable
|
 |
Resistance thermometer EKT 110

|
Immersion or channel palp, sensor PT 100 or PT 1000, stainless steel housing, pressure cast head, mechanical connection G 1/2
Application:
boiler rooms and thermal stations, tank technology, industry ...
|
 |
Resistance thermometer EKT 210, EKT 310

|
Atmospheric or spatial sensor, ABS housing, sensor PT 100 or PT 1000
Application:
external or spatial measurements of temperature in systems of heating or cooling
|
 |
Temperature transmitter TTP 310

|
The transmitter is characterized by great accuracy of temperature measurements. It consists of a sensor PT 100, which is dislocated inside a stainless steel cone, and ABS housing that contains precision electronics.
Application:
measurement of spatial or atmospheric air temperatures (chillers, heat chambers ...)
Technical data:
Power supply (two wire): 9-27 V
Output: current 4-20 mA
Measuring range (on customer demand): -50 ... +50 ° C
|
 |
Temperature probe MT 100

|
MT 100 is an immersible probe. Precision sensor and electronics providing the output current of 4-20mA in a stainless steel housing.
Application:
water temperature measurement in swimming pools, thermal wells, lakes, rivers ...
Technical data:
Power supply (two wire): 9-27 V
Output: current 4-20 mA
Measuring range (on customer demand): -50 ... +70 ° C
|
 |
Temperature transmitters MT 201 und
MT 211

|
Microprocessor transmitter with LED (MT 201) or LCD (MT 211) screen. Stainless steel casing, pressure cast head, multi functional LED screen for reviewing temperature, flow ..., output current 4-20mA, two limit pairs, programmable measuring range.
Application:
boiler rooms and thermal stations, tank installations, industrial facilities ...
Technical data:
Power (two wire): 9 - 27 VDC
Output: current 4-20mA, two limit pairs
Measuring range (programmable): -99 to + 400 ° C
|
| | TOP | |
|
WCS | Conductivity Measurement

Conductivity meters are used for monitoring water resources, lakes or rivers, quality control in hot water systems (soft water)... According to the method of installation they can be of an immersion or "dry-fitting" construction.
|
Conductivity probe MK 100

|
An immersion conductivity probe with automatic temperature compensation and an output current loop
Technical data:
Power supply: 12 ... 24VDC
Output: current 4-20mA
Measuring range: 10 - 2000 uS/cm
Measurement error: <2%
Medium temperature: 0 ... +50 ° C
|
 |
Conductivity transmitter MK 201

|
An immersion conductivity probe with automatic temperature compensation and an output current loop
Technical data:
Power supply: 12 ... 24VDC
Output: current 4-20mA
Measuring range: 10 - 2000 uS/cm
Measurement error: <2%
Medium temperature: 0 ... +50 ° C
|
| TOP |
|
|
WCS | Measuring Transmitters |
 |
Measuring transmitters convert electrical and non-electrical quantities (e.g. temperature – input are temperature sensors or different current and voltage signals) into standard voltage and current signals. We distinguish them either by their housing (independent housing or built in housing, e.g. mounting inside the temperature sensor head) or their concept (with galvanic isolation of input/output/power or without galvanic isolation).
Measuring transmitters of the MPx 3xx family are installed on a DIN rail in the el. cabinet. The electronics are constructed inside a 22mm wide ABS housing. |
Measuring transmitter MPU 301

|
Input: temperature sensor PT 100 (three wire ), DC voltage or DC current. Output: DC voltage (0-5V, 1-5V, 0-10V, 2-10V, power 24VDC).
Application:
measurements of temperatures in automation systems
|
 |
Measuring transmitter MPI 301

|
Input: temperature sensor PT 100 or PT 1000 (three wire), DC voltage, DC current. Output: current 4-20mA, power 24VDC (current loop).
Application:
measurements of temperatures in automation systems
|
 |
Measuring transmitter MPI 331

|
Input: AC current (0-5A, 0-10A) Output: current 4-20mA, power 24VDC (current loop), galvanic isolation of input/output.
Application:
measurement of alternating current of large consumers (engines ...), systems for el. peak reduction ...
|
 |
Measuring transmitter MPI 342

|
Input: DC voltage or DC current (e.g. 4-20mA). Output: current 4-20mA, galvanic isolation of input/output, power 15-27VDC.
Application:
in automation systems with floating mass or in case of large potential differences in galvanic concluded current loops |
 |
Measuring transmitter MPI 100

|
Input temperature sensor PT 100 or PT 1000
output current 4-20mA, programmable measuring range, power 24VDC over a current loop, assembly inside the temperature sensor head
|
 |
Measuring transmitter MFI 300

|
Input impulse from a flow meter or an inductive flow meter or DC current, DC voltage; output current 4-20mA, sum impulses and a limit pair; power 230VAC or 24VDC (option), LCD screen, programmable measuring range.
Application:
flow measuring (flow meter input) or measuring converter with a galvanic isolation of the signal
|
| | TOP | |
|
WCS | Data Logger 
The GSR and PSR data logger families measure and register different quantities such as pressure, level, flow, temperature... Power supply is adapted to the application site. It can be grid, battery or solar powered. According to their construction we distinguish compact loggers and loggers with dislocated electronics. Data transfer may be local, networked or wireless.
|
Data loggers GSR 120 NT and GSR 120NTG

|
The GSR 120 logger family consists of two data loggers: type GSR 120NT which measures and registers levels (or pressure) and temperatures and type GSR 120NTG, which in addition to level (pressure) and temperature measurements records also the conductivity of the media (water).
They are characterized by a compact stainless steel immersion housing, battery or external power supply, communication connection RS 485 and the possibility of connecting a GSM modem for wireless data transmission.
Application:
monitoring of groundwater, surface rivers and lakes ...
Technical data:
Power: battery or grid
Measuring range: 0 to max. 300m, 10 - 2000 uS / cm
Sampling time: 1 second to 24 hours
Memory capacity: 3 x 16.000 data
Protection level: Ip68
|
 |
Data loggers GSR 130NT and GSR 130NTG

|
The GSR 130 logger family ist similar to GSR 120, but the GSR 130 logger measures and registers absolute level (pressure) and therefore needs no vented connection cable. The Data logger GSR 130 NT measures and registers level (pressure) and temperature, the GSR 130 NTG measures and registers level, temperature and also conductivity of the media (water).
The data logger is descended with an ordinary cable-rope at a suitable place in a well and fixed at the top. The data logger has to be taken out of the water for data transmission.
Application:
monitoring of groundwater, wells and other water sources, very deep wells ...
Technical data:
Power: 1 x Li battery 3,6 V, AA
Measuring range: 0 to max. 300m, 10 – 2000 µS/cm
Sampling time: 1 second to 24 hours
Memory capacity: 3 x 16.000 data
Protection level: IP68
|
 |
Portable data logger MRE 120

|
Electronics are encased in an ABS housing, battery and/or grid powered, immersion level, temperature and conductivity (option) gauge with the appropriate length of a special vented cable with Kevlar fibers on a robust reel on wheels.
Application:
monitoring of pumping tests
Technical data:
Input: immersion level or pressure gauge, temperature gauge, pulse from the flow meter, two digital inputs
Power source: battery, grid or both (auto switch)
GSM modem, antenna, ABS housing, IP65 protection
|
 |
Data logger PSR 301

|
PSR 301 can measure and register pressure, temperature and flow (optional) of the media. The electronics along with a LCD display and batteries are located inside the logger head (pressure cast).
The stainless steel housing contains a pressure and a temperature sensor with an G1/2 connector. The connectors on the head serve either for local data transfer or for connecting an external module with a GSM modem.
Technical data:
Power: battery
LCD screen for reviewing the measured quantities
Communication: RS232 or RS485
Sampling time: 1 second to 24 hours
Memory capacity: 3 x 16.000 data
Protection level: IP65
|
| | TOP | |
|
WCS | Mobile Flow Measurement

|
Portable Transit Time Flow and Energy Meter - Ultra TTP

|
The TTP features technology to provide for a precise, and reliable ultrasonic clamp on flow and energy meter.
Application:
Ultra TTP provides a low cost alternative to measuring flow rates with multiple advantages, most notably is the non-invasive, low costs installation. Furthermore, the technology allows for no pressure head loss, no moving parts to maintain or replace, no fluid compatibility issue, and a bi-directional flow range that provides accurate readings at very low and very high flow rates. The device is ideal for spot-checking and troubleshooting thanks to its portable design.
Measured flow rates:
The TTP Flow meter measures eleven flow rates; acre-feet, meters, cubic meters, liters, million liters, kg,
feet, gallons, cubic feet, million gallons, lbs.
The energy meter measures in units of kWh, BTU, MBTU, Tons, kJ, Mwh ...
Ideal for spot checking remote area pipes or where verification is needed. |
 |
Ultra TTP Transducer

|
Technical Data:
Compression mode propagation,
clamp-on
NEMA 6 (IP 67), CPVC, UltemR
Nylon cord grip, PVC cable jacket
-40°C ... +121 ºC
DN50 - DN1500 |
 |
Inductive Flow Meter System MQ 100

|
The inductive flow meter in combination with the measuring transmitter (output current 4-20mA and sum impulses that can connect to a controller input) presents a reliable solution for flow measurements in pipelines.
It is distinguished by a low price (esp. with greater pipe diameters), an easy assembly without draining the pipeline, without expensive constructive work, a great mobility, measurement of very low flow rates, low power consumption and a universal application (one meter type fits many different pipe diameters).
|
| | TOP | |
|
WCS | Mobile Flow Measurement - Waste Water

Remote Monitoring - for Sewage Disposal Systems
|
|
| Range of application from DN 50
| Outlet measurement
| Process water measurement
| Monitoring of emergency outlets
| Determination of rainwater, extraneous
water and indirect discharges
| Calibration for sewer network calculations
| Quick and easy installation
|
| | TOP | |
|
Invasive Measuring Methods |
|
 |
Magnetic inductive procedure

|
| Range of application DN 50 - DN 800
| Installation and removal under operating conditions
| Measuring accuracy ±0,25%
| Measuring section correlating with the pipeline
| For mobile and stationary use |
 |
Procedure according to Puls Doppler

|
| For open channels and partially filled pipes
| Range of application (h) up to 1.3m
| Regardless of the form of the channel
| Installation and removal under operating conditions
| Measuring accuracy ±1%
| No reduction of cross sections |
|
| | TOP | |
|
Non-invasive Measuring Method |
|
| |
Ultrasonic Procedure

|
| Range of application DN 50 - DN 1500
| Easy installation on existing pipelines
| Measuring accuracy ±1%
| No reduction of cross sections
| Regardless of pressure and temperature |
 |
| | TOP | |
|
WCS | Water Loss Control System
In the transportation of water from sources to end consumers some water always gets lost.
Any significant deviation means an additional loss of water.
This means high costs because of expensive electricity used up to pump the water, the necessity find to new resources, pipelines are more burdened and last but not least the government has introduced sanctions - a fee on water loss.
The system consists of a data logger, an inductive flow meter and a pressure transmitter. The data is stored in the memory unit. With the help of a GSM modem the archived data (daily) or alarm information (when the set parameters are breached) can be sent wirelessly to a designated location.
With the analysis of information provided by individual data loggers deviations or differences in the flow and pressure can be detected at different time intervals ( at night, weekdays or on weekends ...)
Any significant deviation means an additional loss of water.
Depending on the data logger's location we can quickly response and find the area that has to be improved. The power supply can be adapted to the application location, the system can be grid, battery or solar powered. A quick and easy assembly provide good mobility of the system.
|

|
Application:
The measuring system allows measurements and registration of pressure, temperature and flow, as well
as indication of water intrusion and unauthorized entry into the facility.
Power supply can be battery, 230 VAC grid or solar. Data from the data logger can be transferred to a PC
locally or wireless (installed GSM modem).
Inductive flow meter:
mounting on the pipeline without flow interruption, connected to the data logger, battery, solar or grid powered, mechanical connectionG5/4, measurements of very low flows, robust construction |
 |
| | TOP | |
|
WCS | Accessories

Die Widerstandsthermometer haben Temperatursensoren in verschiedenen Gehäusen, die Temperaturmessgeräte aber auch Elektronik, die einen Ausgang durch die Stromschleife hat, bei einigen Messgeräten auch eine Temperaturanzeige auf dem LED oder LCD Bildschirm.
|
Controllers MR 102 and MR 204

|
Universal microprocessor controllers used for measurements and control of
electrical and non-electrical quantities. LED display shows the measured
quantity (temperature, level, pressure ...) and in settings mode also all switching
levels (limit pairs). The measuring range and switching levels (switch-on and
switch-off ) are programmable.
Application:
waterworks (level control), heat systems (temperature
regulation), industry ...
Technical Data:
Power: MR 102: 12 or 24VDC; MR 204: 230V, 50Hz
Input: DC current (4-20mA, 0-20mA), DC voltage, potentiometer, PTC
sensor, pt100, pt 1000; Output: MR 102: 2 relay; MR 204: 4 relays
Display: LED screen (MR 102): 3 digit (MR 204): 4 digit, LED diode
indication for individual relay switch-on; Installation dimensions of the front
panel: MR 102: 72 x 48 mm; MR 204: 96 x 48 mm
|
 |
Digital indicator MI 101 and MI 201

|
Universal digital indicator installed into the door of el. cabinets used for
reviewing electrical and non-electrical quantities. A LED display shows the measured quantity (temperature, level, pressure ...).
Application:
waterworks, heat systems technology, industry ...
Technical Data:
Power: 12 or 24VDC (MI 101), 230VAC (MI 201)
Input: DC current (4-20mA, 0-20mA), DC voltage, potentiometer, PTC
sensor, PT100, PT 1000; programmable measuring range (review)
Display: LED display 3 digit (MI 101), 4 digit (MI 201)
|
 |
Overvoltage protection circuits PZV 301 and PZV 310
 
|
Overvoltage protection circuits protect current loops or communication lines
from an excess voltage caused by atmospheric surges, magnetic induction etc.
They can be mounted on a standard rail in the el. cabinet (PZV 30 ) or on the
wall (PZV 310).
Application:
Automation systems (waterworks, heat systems, industry... )
Technical Data:
Rated voltage: 24V (or on customer demand)
Number of protected pairs: 1 (asymmetric and symmetric protection)
Drainage stack for the current wave of 8/20us: 10kA
|
|
Signal board panel SI 200

|
The signal board panel displays the most important information on developments inside the drive, with LED diodes in different colors.
Application:
in automation systems ( on the el. cabinet door)
Technical Data:
Power supply: 24VDC
Input: up to 8 signals 24VDC,
|
 |
Relay cards ORE 300

|
The relay cards have 1 relay (ORE 300-1) or 4 relays (ORE 300-4). They are
used for galvanic isolation of grid voltage 230VAC and control voltage.
Application:
in the function of pressure, level or temperature switches (- see
pressure gauges, level and temperature) or independent.
Technical Data:
Number of relays: 1, 4;
Control voltage: 12, 24VDC, VAC
|
 |
|

|
|
Send us your request or inquiry by email, we will be pleased to advise you.
|
| | TOP | |
|